Temac root products
Technical parameter
Temac No asbestos root brand is ,Concrete type and technical parameter,etc. are seen and tabulated
Install guidance
Correct a root is installed to lengthening service life , it is very important to reduce the maintenance cost, whether so mounting disc root please according to following procedure:
n Pull out and fetch tools to take out a root with special-purpose a root, clear
up the sealed letter.
n It check have axle because the skew and the excessive to wear and tear for side
direction , guarantee axle and interval of letter not sealed the even, can
exceed not wanting not for records of 3% of widths of rooting interval size, the
partial displacement of the axle can't exceed 0 of the axle foot-paths 0.1%.
n Cut first circle records of especially important root, should accomplish
carefully, its length needs to make testing at the axle , other cut of a root
that enclose can be according to this. Need every circle to interlock and go on
according to 180 degrees or the direction of 90 degrees while clogging a root.
n If the condition permits , the mounting disc root can twine and clog along the
axle.
|
Medium |
Specified working pressure of the valve(Pn) |
Pressure of packing of a root (Pi) |
Liquid |
0-40bar |
2XPn(Minimum 5N/mm2
) |
>40bar |
1.5XPN |
Gas |
0-40bar |
5XPn(Minimum 10N/mm2) |
40-200bar |
2.5-5XPn |
>200bar |
1.5XPn |
|
Attention:
Mounting disc is it rotate valve stem , guarantee records of pressure that root
being packed reach the above giving a recommendation value constantly to want at
the root, at the same time the valve be able to be opened flexibly. After using
24 hours , need to reexamine the tight strength that the sealed letter
pigeonholes , so as to ensure the pressure of packing of a root.
|
To the best pressure that a root packs of the pump:
To pack pressure (Pi )1 , medium of working pressure generally sealed records of root of letter of pump. 5-2 times, but pi, still with a lot of factors, the structure like the pump in fact, the situation of the sealed letter, medium temperature, viscidity,etc. have something to do, decision this pi need in scene according to actual working condition and make, in order to guarantee sealing property of pump fully. In the mounting disc root, must be careful, after putting a root well, must start the pump , then could begin to seal the bolt that the letter pigeonholed closely slowly , until the fact that pump does not leak, observe one minute, can urgent half a nut so as to ensure and seal according to situation.
|
|